-40%
TR-55i Optical Datalogger with IR Connectivity
$ 157.24
- Description
- Size Guide
Description
TR-55i Optical Datalogger with IR ConnectivityOur TR-5i Series data loggers are designed to measure and record temperature, voltage, 4-20mA, or pulse count. The body of the data loggers are water resistant and can be used in an environment of -40 °C to 80 °C. Moreover, battery-powered operation means the loggers can be placed anywhere without the need for AC power. The data recorded by the loggers can be transferred to PC via separately sold "Communication Port TR-50U2" or "Data Collector TR-57DCi", whereby users can analyze the data and view in graph form. Furthermore, our Data Collector TR-57DCi enables on-site data collection and viewing of data; no longer it is necessary to manually gather the data loggers. TR-55i-TC TR-55i-Pt TR-55i-V TR-55i-mA TR-55i-P Measurement Channels Temperature 1ch Temperature 1ch Voltage 1ch 4-20mA 1ch Pulse Count 1ch Sensor Thermocouple: Type K, J, T, S Pt100, Pt1000 (3-wire) - - - Measurement Units °C, °F °C, °F V, mV mA P Measurement Range -199 to 1700 °C -199 to 600 °C 0 to 22 V 0 to 20 mA(Operationalup to 40 mA) Input Signal:¥ Non-voltage Contact Input¥ Voltage Input (0 to 27 V)Detection VoltageLo: 0.5 V or lessHi: 2.5V or moreInput Impedance:Approx. 100 KΩ pull upChattering Filter:ON: 15 Hz or lessOFF: 3.5 kHz or lessMaximum Count61,439 / Recording Interval Accuracy(*1) Thermocouple Measurement ±0.3 °C + 0.3 % rdg[Type K, J, T] ±1 °C + 0.3 % rdg [Type S]Cold Junction Compensation ±0.3 °C [10 to 40 °C] ±0.5 °C [-40 to 10 °C / 40 to 80 °C] ±0.3 °C + 0.3 % rdg [10 to 40 °C] ±0.5 °C + 0.3 % rdg [-40 to 10 °C / 40 to 80 °C] ±0.5 mV + 0.3 % rdg [10 to 40 °C] ±1 mV + 0.5 % rdg [-40 to 10 °C / 40 to 80 °C] ±0.05 mA + 0.3 % rdg [10 to 40 °C] ±0.1mA + 0.3 % rdg [-40 to 10 °C / 40 to 80 °C] Note: The above temperatures [__ °C] are for the operating environment of the Input Module. MeasurementResolution Type K, J, T : 0.1 °CType S : Approx. 0.2 °C 0.1 °C up to 400mV: at 0.1mV, up to 800mV: at 0.2mV, up to 999mV: at 0.4mV, up to 3.2V: at 1mV, up to 6.5V: at 2mV, up to 9.999V: at 4mV, up to 22V: at 10mV 0.01 mA Logging Capacity 16,000 readings Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. Recording Mode Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) LCD Display Items Measurements, Recording Status, Battery Life Warning, etc. CommunicationInterfaces Optical Communication (proprietary protocol)Infrared(IR) Communication (IrPHY 1.2 low power) Power(*2) Lithium Battery (LS14250) x 1 Battery Life(*3) Approx. 14 months (10 months with IR Communication Enabled) Approx. 24 months (14 months with IR Communication Enabled) Approx. 16 months (11 months with IR Communication Enabled) Approx. 16 months (11 months with IR Communication Enabled) Approx. 16 to 24 months (11 to 18 months with IR Communication Enabled) Dimensions H 62 mm x W 47 mm x D 19 mm (excluding protrusions and Input Module) Weight Approx. 55 g (including battery / excluding Input Module) Operating Environment -40 to 80 °C Waterproof Capacity(*4) IP64: Splash proof (rated for use in daily life) Note: Input Module is not water resistant. Accessories Input Module(TCM-3010) Input Module(PTM-3010) Input Module(VIM-3010) Input Module(AIM-3010) Input Module(PIC-3150) Lithium Battery (LS14250), Strap, User's Manual (Warranty Included) Data Collection Devices Communication Port: TR-50U2, TR-50UData Collector: TR-57DCi (*1) "rdg" stands for reading. (*2) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement. (*3) Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life. When the infrared communication function is enabled, battery life may be shortened further if the unit is used under the inverter type fluorescent lighting. (*4) This is the waterproof capacity of the data logger with the Input Module connected. Application Examples * For temperature management of refrigerated and frozen goods* For temperature management when curing concrete* Performance testing of thermal insulation coating* For performance evaluation of air conditioning units* For tracking food temperature during transport* For temperature recording of switching equipment and transformers * For temperature recording of combustion furnaces and blast furnaces* Recording measurements taken from various measuring instruments such as flow meters, pressure meters, power meters, and analyzers* Recording and managing measurement signals from various devices and equipment* For the measurement of output pulse
TR-55i Optical Datalogger with IR Connectivity
Our TR-5i Series data loggers are designed to measure and record temperature, voltage, 4-20mA, or pulse count. The body of the data loggers are water resistant and can be uséd in an environment of -40 °C to 80 °C. Moreover, battery-powered operation means the loggers can be placed anywhere without the need for AC power.
The data recorded by the loggers can be transferred to PC via separately sold "Communication Port TR-50U2" or "Data Collector TR-57DCi", whereby users can analyze the data and view in graph form.
Furthermore, our Data Collector TR-57DCi enables on-site data collection and viewing of data; no longer it is necessary to manually gather the data loggers.
TR-55i-TC
TR-55i-Pt
TR-55i-V
TR-55i-mA
TR-55i-P
Measurement Channels
Temperature 1ch
Temperature 1ch
Voltage 1ch
4-20mA 1ch
Pulse Count 1ch
Sensor
Thermocouple: Type K, J, T, S
Pt100, Pt1000
(3-wire)
-
-
-
Measurement Units
°C, °F
°C, °F
V, mV
mA
P
Measurement Range
-199 to 1700 °C
-199 to 600 °C
0 to 22 V
0 to 20 mA
(Operational
up to 40 mA)
Input Signal:
¥ Non-voltage Contact Input
¥ Voltage Input (0 to 27 V)
Detection Voltage
Lo: 0.5 V or less
Hi: 2.5V or more
Input Impedance:
Approx. 100 KΩ pull up
Chattering Filter:
ON: 15 Hz or less
OFF: 3.5 kHz or less
Maximum Count
61,439 / Recording Interval
Accuracy
(*1)
Thermocouple Measurement
±0.3 °C + 0.3 % rdg[Type K, J, T]
±1 °C + 0.3 % rdg [Type S]
Cold Junction Compensation
±0.3 °C [10 to 40 °C]
±0.5 °C [-40 to 10 °C / 40 to 80 °C]
±0.3 °C + 0.3 % rdg [10 to 40 °C]
±0.5 °C + 0.3 % rdg [-40 to 10 °C / 40 to 80 °C]
±0.5 mV + 0.3 % rdg [10 to 40 °C]
±1 mV + 0.5 % rdg [-40 to 10 °C / 40 to 80 °C]
±0.05 mA + 0.3 % rdg [10 to 40 °C]
±0.1mA + 0.3 % rdg [-40 to 10 °C / 40 to 80 °C]
Note: The above temperatures [__ °C] are for the operating environment of the Input Module.
Measurement
Resolution
Type K, J, T :
0.1 °C
Type S :
Approx. 0.2 °C
0.1 °C
up to 400mV: at 0.1mV,
up to 800mV: at 0.2mV,
up to 999mV: at 0.4mV,
up to 3.2V: at 1mV,
up to 6.5V: at 2mV,
up to 9.999V: at 4mV,
up to 22V: at 10mV
0.01 mA
Logging Capacity
16,000 readings
Recording Interval
Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode
Endless (Overwrite oldest data when capacity is full)
or One Time (Stop recording when capacity is full)
LCD Display Items
Measurements, Recording Status, Battery Life Warning, etc.
Communication
Interfaces
Optical Communication (proprietary protocol)
Infrared(IR) Communication (IrPHY 1.2 low power)
Power
(*2)
Lithium Battery (LS14250) x 1
Battery Life
(*3)
Approx. 14 months (10 months with IR Communication Enabled)
Approx. 24 months (14 months with IR Communication Enabled)
Approx. 16 months (11 months with IR Communication Enabled)
Approx. 16 months (11 months with IR Communication Enabled)
Approx. 16 to 24 months (11 to 18 months with IR Communication Enabled)
Dimensions
H 62 mm x W 47 mm x D 19 mm
(excluding protrusions and Input Module)
Weight
Approx. 55 g (including battery / excluding Input Module)
Operating Environment
-40 to 80 °C
Waterproof Capacity
(*4)
IP64: Splash proof (rated for use in daily life) Note: Input Module is not water resistant.
Accessories
Input Module
(TCM-3010)
Input Module
(PTM-3010)
Input Module
(VIM-3010)
Input Module
(AIM-3010)
Input Module
(PIC-3150)
Lithium Battery (LS14250), Strap, User's Manual (Warranty Included)
Data Collection Devices
Communication Port: TR-50U2, TR-50U
Data Collector: TR-57DCi
(*1) "rdg" stands for reading.
(*2) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement.
(*3) Battery life varies depending upon the ambient temperature in which it is uséd, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life. When the infrared communication function is enabled, battery life may be shortened further if the unit is uséd under the inverter type fluorescent lighting.
(*4) This is the waterproof capacity of the data logger with the Input Module connected.
Application Examples
* For temperature management of refrigerated and frozen goods
* For temperature management when curing concrete
* Performance testing of thermal insulation coating
* For performance evaluation of air conditioning units
* For tracking food temperature during transport
* For temperature recording of switching equipment and transformers
* For temperature recording of combustion furnaces and blast furnaces
* Recording measurements taken from various measuring instruments such as flow meters, pressure meters, power meters, and analyzers
* Recording and managing measurement signals from various devices and equipment
* For the measurement of output pulse
×
Tell a friend
Visit store
Watch now
Postage info
Click the Postage tab above the listing description for more info
Click the Postage tab above the listing description for more info!
Additional delivery notes
PICK UP OPTION
Sorry, our items are NOT available for pick-up.
PAYING VIA PAYPAL
We accept PayPal on our all our items so you can shop with confidence.
Simple choose the PayPal option when proceeding through the checkout.
Additional Information
No additional information at this time
Ask seller a question
You might also like
1236-17 Thermometer
1236-70 Espresso Thermometer
1246-01 Pocket Test Thermometer
1246-02 Pocket Test Thermometer
Contact
To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
Ask seller a question
© Tech Instrumentation
Postage
Click the Postage tab above the listing description for more info
Payment
Accepted Payment Methods
PayPal
Returns
Returns are accepted
Items must be returned within 30 days of the auction ending
Buyer will pay for return shipping.
eBay integration
by