-40%

TR-55i Optical Datalogger with IR Connectivity

$ 157.24

Availability: 100 in stock
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • Item must be returned within: 30 Days
  • Brand: TandD
  • Condition: New
  • MPN: Does Not Apply
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money back or replacement (buyer's choice)

    Description

    TR-55i Optical Datalogger with IR Connectivity
    Our TR-5i Series data loggers are designed to measure and record temperature, voltage, 4-20mA, or pulse count. The body of the data loggers are water resistant and can be used in an environment of -40 °C to 80 °C. Moreover, battery-powered operation means the loggers can be placed anywhere without the need for AC power. The data recorded by the loggers can be transferred to PC via separately sold "Communication Port TR-50U2" or "Data Collector TR-57DCi", whereby users can analyze the data and view in graph form. Furthermore, our Data Collector TR-57DCi enables on-site data collection and viewing of data; no longer it is necessary to manually gather the data loggers. TR-55i-TC TR-55i-Pt TR-55i-V TR-55i-mA TR-55i-P Measurement Channels Temperature 1ch Temperature 1ch Voltage 1ch 4-20mA 1ch Pulse Count 1ch Sensor Thermocouple: Type K, J, T, S Pt100, Pt1000 (3-wire) - - - Measurement Units °C, °F °C, °F V, mV mA P Measurement Range -199 to 1700 °C -199 to 600 °C 0 to 22 V 0 to 20 mA(Operationalup to 40 mA) Input Signal:¥ Non-voltage Contact Input¥ Voltage Input (0 to 27 V)Detection VoltageLo: 0.5 V or lessHi: 2.5V or moreInput Impedance:Approx. 100 KΩ pull upChattering Filter:ON: 15 Hz or lessOFF: 3.5 kHz or lessMaximum Count61,439 / Recording Interval Accuracy(*1) Thermocouple Measurement ±0.3 °C + 0.3 % rdg[Type K, J, T] ±1 °C + 0.3 % rdg [Type S]Cold Junction Compensation ±0.3 °C [10 to 40 °C] ±0.5 °C [-40 to 10 °C / 40 to 80 °C] ±0.3 °C + 0.3 % rdg [10 to 40 °C] ±0.5 °C + 0.3 % rdg [-40 to 10 °C / 40 to 80 °C] ±0.5 mV + 0.3 % rdg [10 to 40 °C] ±1 mV + 0.5 % rdg [-40 to 10 °C / 40 to 80 °C] ±0.05 mA + 0.3 % rdg [10 to 40 °C] ±0.1mA + 0.3 % rdg [-40 to 10 °C / 40 to 80 °C] Note: The above temperatures [__ °C] are for the operating environment of the Input Module. MeasurementResolution Type K, J, T : 0.1 °CType S : Approx. 0.2 °C 0.1 °C up to 400mV: at 0.1mV, up to 800mV: at 0.2mV, up to 999mV: at 0.4mV, up to 3.2V: at 1mV, up to 6.5V: at 2mV, up to 9.999V: at 4mV, up to 22V: at 10mV 0.01 mA Logging Capacity 16,000 readings Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. Recording Mode Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) LCD Display Items Measurements, Recording Status, Battery Life Warning, etc. CommunicationInterfaces Optical Communication (proprietary protocol)Infrared(IR) Communication (IrPHY 1.2 low power) Power(*2) Lithium Battery (LS14250) x 1 Battery Life(*3) Approx. 14 months (10 months with IR Communication Enabled) Approx. 24 months (14 months with IR Communication Enabled) Approx. 16 months (11 months with IR Communication Enabled) Approx. 16 months (11 months with IR Communication Enabled) Approx. 16 to 24 months (11 to 18 months with IR Communication Enabled) Dimensions H 62 mm x W 47 mm x D 19 mm (excluding protrusions and Input Module) Weight Approx. 55 g (including battery / excluding Input Module) Operating Environment -40 to 80 °C Waterproof Capacity(*4) IP64: Splash proof (rated for use in daily life) Note: Input Module is not water resistant. Accessories Input Module(TCM-3010) Input Module(PTM-3010) Input Module(VIM-3010) Input Module(AIM-3010) Input Module(PIC-3150) Lithium Battery (LS14250), Strap, User's Manual (Warranty Included) Data Collection Devices Communication Port: TR-50U2, TR-50UData Collector: TR-57DCi (*1) "rdg" stands for reading. (*2) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement. (*3) Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life. When the infrared communication function is enabled, battery life may be shortened further if the unit is used under the inverter type fluorescent lighting. (*4) This is the waterproof capacity of the data logger with the Input Module connected. Application Examples * For temperature management of refrigerated and frozen goods* For temperature management when curing concrete* Performance testing of thermal insulation coating* For performance evaluation of air conditioning units* For tracking food temperature during transport* For temperature recording of switching equipment and transformers * For temperature recording of combustion furnaces and blast furnaces* Recording measurements taken from various measuring instruments such as flow meters, pressure meters, power meters, and analyzers* Recording and managing measurement signals from various devices and equipment* For the measurement of output pulse
    TR-55i Optical Datalogger with IR Connectivity
    Our TR-5i Series data loggers are designed to measure and record temperature, voltage, 4-20mA, or pulse count. The body of the data loggers are water resistant and can be uséd in an environment of -40 °C to 80 °C. Moreover, battery-powered operation means the loggers can be placed anywhere without the need for AC power.
    The data recorded by the loggers can be transferred to PC via separately sold "Communication Port TR-50U2" or "Data Collector TR-57DCi", whereby users can analyze the data and view in graph form.
    Furthermore, our Data Collector TR-57DCi enables on-site data collection and viewing of data; no longer it is necessary to manually gather the data loggers.
    TR-55i-TC
    TR-55i-Pt
    TR-55i-V
    TR-55i-mA
    TR-55i-P
    Measurement Channels
    Temperature 1ch
    Temperature 1ch
    Voltage 1ch
    4-20mA 1ch
    Pulse Count 1ch
    Sensor
    Thermocouple: Type K, J, T, S
    Pt100, Pt1000
    (3-wire)
    -
    -
    -
    Measurement Units
    °C, °F
    °C, °F
    V, mV
    mA
    P
    Measurement Range
    -199 to 1700 °C
    -199 to 600 °C
    0 to 22 V
    0 to 20 mA
    (Operational
    up to 40 mA)
    Input Signal:
    ¥ Non-voltage Contact Input
    ¥ Voltage Input (0 to 27 V)
    Detection Voltage
    Lo: 0.5 V or less
    Hi: 2.5V or more
    Input Impedance:
    Approx. 100 KΩ pull up
    Chattering Filter:
    ON: 15 Hz or less
    OFF: 3.5 kHz or less
    Maximum Count
    61,439 / Recording Interval
    Accuracy
    (*1)
    Thermocouple Measurement
    ±0.3 °C + 0.3 % rdg[Type K, J, T]
    ±1 °C + 0.3 % rdg [Type S]
    Cold Junction Compensation
    ±0.3 °C [10 to 40 °C]
    ±0.5 °C [-40 to 10 °C / 40 to 80 °C]
    ±0.3 °C + 0.3 % rdg [10 to 40 °C]
    ±0.5 °C + 0.3 % rdg [-40 to 10 °C / 40 to 80 °C]
    ±0.5 mV + 0.3 % rdg [10 to 40 °C]
    ±1 mV + 0.5 % rdg [-40 to 10 °C / 40 to 80 °C]
    ±0.05 mA + 0.3 % rdg [10 to 40 °C]
    ±0.1mA + 0.3 % rdg [-40 to 10 °C / 40 to 80 °C]
    Note: The above temperatures [__ °C] are for the operating environment of the Input Module.
    Measurement
    Resolution
    Type K, J, T :
    0.1 °C
    Type S :
    Approx. 0.2 °C
    0.1 °C
    up to 400mV: at 0.1mV,
    up to 800mV: at 0.2mV,
    up to 999mV: at 0.4mV,
    up to 3.2V: at 1mV,
    up to 6.5V: at 2mV,
    up to 9.999V: at 4mV,
    up to 22V: at 10mV
    0.01 mA
    Logging Capacity
    16,000 readings
    Recording Interval
    Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
    Recording Mode
    Endless (Overwrite oldest data when capacity is full)
    or One Time (Stop recording when capacity is full)
    LCD Display Items
    Measurements, Recording Status, Battery Life Warning, etc.
    Communication
    Interfaces
    Optical Communication (proprietary protocol)
    Infrared(IR) Communication (IrPHY 1.2 low power)
    Power
    (*2)
    Lithium Battery (LS14250) x 1
    Battery Life
    (*3)
    Approx. 14 months (10 months with IR Communication Enabled)
    Approx. 24 months (14 months with IR Communication Enabled)
    Approx. 16 months (11 months with IR Communication Enabled)
    Approx. 16 months (11 months with IR Communication Enabled)
    Approx. 16 to 24 months (11 to 18 months with IR Communication Enabled)
    Dimensions
    H 62 mm x W 47 mm x D 19 mm
    (excluding protrusions and Input Module)
    Weight
    Approx. 55 g (including battery / excluding Input Module)
    Operating Environment
    -40 to 80 °C
    Waterproof Capacity
    (*4)
    IP64: Splash proof (rated for use in daily life) Note: Input Module is not water resistant.
    Accessories
    Input Module
    (TCM-3010)
    Input Module
    (PTM-3010)
    Input Module
    (VIM-3010)
    Input Module
    (AIM-3010)
    Input Module
    (PIC-3150)
    Lithium Battery (LS14250), Strap, User's Manual (Warranty Included)
    Data Collection Devices
    Communication Port: TR-50U2, TR-50U
    Data Collector: TR-57DCi
    (*1) "rdg" stands for reading.
    (*2) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement.
    (*3) Battery life varies depending upon the ambient temperature in which it is uséd, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life. When the infrared communication function is enabled, battery life may be shortened further if the unit is uséd under the inverter type fluorescent lighting.
    (*4) This is the waterproof capacity of the data logger with the Input Module connected.
    Application Examples
    * For temperature management of refrigerated and frozen goods
    * For temperature management when curing concrete
    * Performance testing of thermal insulation coating
    * For performance evaluation of air conditioning units
    * For tracking food temperature during transport
    * For temperature recording of switching equipment and transformers
    * For temperature recording of combustion furnaces and blast furnaces
    * Recording measurements taken from various measuring instruments such as flow meters, pressure meters, power meters, and analyzers
    * Recording and managing measurement signals from various devices and equipment
    * For the measurement of output pulse
    ×
    Tell a friend
    Visit store
    Watch now
    Postage info
    Click the Postage tab above the listing description for more info
    Click the Postage tab above the listing description for more info!
    Additional delivery notes
    PICK UP OPTION
    Sorry, our items are NOT available for pick-up.
    PAYING VIA PAYPAL
    We accept PayPal on our all our items so you can shop with confidence.
    Simple choose the PayPal option when proceeding through the checkout.
    Additional Information
    No additional information at this time
    Ask seller a question
    You might also like
    1236-17 Thermometer
    1236-70 Espresso Thermometer
    1246-01 Pocket Test Thermometer
    1246-02 Pocket Test Thermometer
    Contact
    To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
    Ask seller a question
    © Tech Instrumentation
    Postage
    Click the Postage tab above the listing description for more info
    Payment
    Accepted Payment Methods
    PayPal
    Returns
    Returns are accepted
    Items must be returned within 30 days of the auction ending
    Buyer will pay for return shipping.
    eBay integration
    by