-40%

RTR-501 Wireless Thermo Recorder

$ 88.21

Availability: 20 in stock
  • All returns accepted: Returns Accepted
  • Condition: New
  • Return shipping will be paid by: Buyer
  • MPN: Does Not Apply
  • Restocking Fee: No
  • Brand: TandD
  • Item must be returned within: 30 Days
  • Refund will be given as: Money back or replacement (buyer's choice)

    Description

    RTR-501 Wireless Thermo Recorder
    RTR-501 T&D RTR-501: With Internal Temperature SensorThis wireless internal sensor thermo recorder provides optimum waterproof and dust-proof capabilities. This is the perfect Data Logger for use in harsh environments: whether that may be indoor frozen or refrigerated storage or high humidity, high dust outdoor applications. Moreover, the compact lightweight design means it can be placed just about anywhere. Download Download Data via Wireless Communication with a Base Unit. Recorded data can be downloaded from RTR-500 Series Data Loggers (Remote Units) via wireless communication with a Base Unit. The wireless communication range between a Remote Unit and a Base Unit is about 150 meters [500 ft]. By registering an RTR-500 as a Repeater, it can be used to expand the wireless communication range.RTR-501/502/505: Maximum of 16,000 readings16,000 readings means you can record every one second and still log four and a half hours of data; or at a recording interval * of 60 minutes you can keep logging for 666 days. A Base Unit can download via wireless communication one RTR-501, RTR-502, or RTR-505 Remote Unit at full logging capacity (16,000 readings) in about two minutes.Low Energy Consumption DesignRTR-501/502/503/505/507The RTR-500 Series Data Loggers use one Lithium Battery (LS14250). At normal temperature, if recorded data is downloaded once a day or if monitoring is carried out once every ten minutes, the estimated battery life will be about ten months.Model names which include "L" are designed with a large capacity battery pack. Under the same conditions, L-type models will continue for about four years without the need to change the battery.* Battery life varies depending upon the type of battery, the measuring environment, and the frequency of communication. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life. Calibration It is possible to make adjustments to measurements for each RTR-500 Series Remote Unit by using the exclusive application "Adjustment Tools". Specifications FCC model / CE model RTR-501/501L, RTR-502/502L, RTR-503/503L Measurement Channels Temperature 1ch (Internal) Temperature 1ch (External) Temperature 1ch, Humidity 1ch (External) Sensor Thermistor Thermistor Thermistor Polymer Resistance Measurement Units °C, °F °C, °F °C, °F % Measurement Range -40 to 80 °C -60 to 155 °C 0 to 55 °C 10 to 95%RH Accuracy Avg ±0.5 °C Avg ±0.3 °C [-20 to 80 °C] Avg ±0.5 °C [-40 to -20 °C /80 to 110 °C] Avg ±1.0 °C [-60 to -40 °C /110 to 155 °C] Avg ±0.3 °C ±5%RH [at 25 °C and 50%RH] Measurement Resolution 0.1 °C 0.1 °C 0.1 °C 1%RHResponse Time (90%): Approx. 35 min. Approx. 47 min.(L Type) Thermal Time Constant: Approx. 30 sec. (in air) Approx. 4 sec. (in agitated water) Response Time (90%): Approx. 80 sec. (in air) Approx. 7 sec. (in agitated water) Response Time (90%): Approx. 7 min. Logging Capacity 16,000 readings 8,000 data sets (One data set consists of readings for multiple channels.) Recording Intervals Select from 15 choices: 1,2,5,10,15,20,30 sec. or 1,2,5,10,15,20,30,60 min.Recording Mode(*1) Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)LCD Display Items Measurements (alternating display for multiple channel devices), Battery Life Warning, etc.Communication Interfaces Wireless Communication (Short Range Radio Communication):FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW)ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW) Optical Communication Wireless Transmission Range Approx. 150 meters (500 ft) if direct and unobstructed Power Lithium Battery: LS14250(*2) x 1 L Type: Large Capacity Battery Adaptor Kit / Battery Life (*4) About 10 months L Type: About 4 years Dimensions H 62 mm x W 47 mm x D 19 mm L type: H 62 mm x W 47 mm x D 46.5 mm (excluding protrusions and sensor) Operating Environment -40 to 80 °C (-30 to 80 °C during wireless communications) Waterproof Capacity IP67: immersion proof IP64: Splash proof (rated for use in daily life) (*5) IP64: Splash proof (rated for use in daily life) (*5) Note: Sensor is not water resistant. Compatible Base Units RTR-500, RTR-500NW/500AW, RTR-500DC, RTR-500GSM(1) Only "Endless" is available when using RTR-500W for Windows or RTR-500GSM for Windows.(2) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement.(3) When using RTR-500B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized distributor.(4) Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way.(5) This is the waterproof capacity of the data logger with the sensor connected.
    RTR-501 Wireless Thermo Recorder
    RTR-501
    T&D RTR-501: With Internal Temperature Sensor
    This wireless internal sensor thermo recorder provides optimum waterproof and dust-proof capabilities. This is the perfect Data Logger for use in harsh environments: whether that may be indoor frozen or refrigerated storage or high humidity, high dust outdoor applications. Moreover, the compact lightweight design means it can be placed just about anywhere.
    Download
    Download Data via Wireless Communication with a Base Unit.  Recorded data can be downloaded from RTR-500 Series Data Loggers (Remote Units) via wireless communication with a Base Unit. The wireless communication range between a Remote Unit and a Base Unit is about 150 meters [500 ft]. By registering an RTR-500 as a Repeater, it can be uséd to expand the wireless communication range.
    RTR-501/502/505: Maximum of 16,000 readings
    16,000 readings means you can record every one second and still log four and a half hours of data; or at a recording interval * of 60 minutes you can keep logging for 666 days. A Base Unit can download via wireless communication one RTR-501, RTR-502, or RTR-505 Remote Unit at full logging capacity (16,000 readings) in about two minutes.
    Low Energy Consumption Design
    RTR-501/502/503/505/507
    The RTR-500 Series Data Loggers use one Lithium Battery (LS14250). At normal temperature, if recorded data is downloaded once a day or if monitoring is carried out once every ten minutes, the estimated battery life will be about ten months.
    Model names which include "L" are designed with a large capacity battery pack. Under the same conditions, L-type models will continue for about four years without the need to change the battery.
    * Battery life varies depending upon the type of battery, the measuring environment, and the frequency of communication. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
    Calibration
    It is possible to make adjustments to measurements for each RTR-500 Series Remote Unit by using the exclusive application "Adjustment Tools".
    Specifications
    FCC model / CE model
    RTR-501/501L, RTR-502/502L, RTR-503/503L
    Measurement Channels Temperature 1ch (Internal) Temperature 1ch (External) Temperature 1ch, Humidity 1ch (External)
    Sensor Thermistor Thermistor Thermistor Polymer Resistance
    Measurement Units °C, °F °C, °F °C, °F %
    Measurement Range -40 to 80 °C -60 to 155 °C 0 to 55 °C 10 to 95%RH
    Accuracy
    Avg ±0.5 °C Avg ±0.3 °C [-20 to 80 °C]
    Avg ±0.5 °C [-40 to -20 °C /80 to 110 °C]
    Avg ±1.0 °C [-60 to -40 °C /110 to 155 °C]
    Avg ±0.3 °C ±5%RH [at 25 °C and 50%RH]
    Measurement Resolution 0.1 °C 0.1 °C 0.1 °C 1%RH
    Response Time (90%):
    Approx. 35 min.
    Approx. 47 min.(L Type) Thermal Time Constant:
    Approx. 30 sec. (in air)
    Approx. 4 sec. (in agitated water)
    Response Time (90%):
    Approx. 80 sec. (in air)
    Approx. 7 sec. (in agitated water)
    Response Time (90%): Approx. 7 min.
    Logging Capacity 16,000 readings 8,000 data sets (One data set consists of readings for multiple channels.)
    Recording Intervals Select from 15 choices:
    1,2,5,10,15,20,30 sec. or 1,2,5,10,15,20,30,60 min.
    Recording Mode(*1) Endless (Overwrite oldest data when capacity is full)
    or One Time (Stop recording when capacity is full)
    LCD Display Items Measurements (alternating display for multiple channel devices), Battery Life Warning, etc.
    Communication Interfaces Wireless Communication (Short Range Radio Communication):
    FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW)
    ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW)
    Optical Communication
    Wireless Transmission Range Approx. 150 meters (500 ft) if direct and unobstructed
    Power Lithium Battery: LS14250(*2) x 1
    L Type: Large Capacity Battery Adaptor Kit /
    Battery Life (*4) About 10 months
    L Type: About 4 years
    Dimensions H 62 mm x W 47 mm x D 19 mm
    L type: H 62 mm x W 47 mm x D 46.5 mm
    (excluding protrusions and sensor)
    Operating Environment
    -40 to 80 °C (-30 to 80 °C during wireless communications)
    Waterproof Capacity IP67: immersion proof IP64: Splash proof (rated for use in daily life) (*5) IP64: Splash proof (rated for use in daily life) (*5)
    Note: Sensor is not water resistant.
    Compatible Base Units RTR-500, RTR-500NW/500AW, RTR-500DC, RTR-500GSM
    (1) Only "Endless" is available when using RTR-500W for Windows or RTR-500GSM for Windows.
    (2) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement.
    (3) When using RTR-500B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized distributor.
    (4) Battery life varies depending upon the ambient temperature in which it is uséd, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way.
    (5) This is the waterproof capacity of the data logger with the sensor connected.
    ×
    Tell a friend
    Visit store
    Watch now
    Postage info
    Click the Postage tab above the listing description for more info
    Click the Postage tab above the listing description for more info!
    Additional delivery notes
    PICK UP OPTION
    Sorry, our items are NOT available for pick-up.
    PAYING VIA PAYPAL
    We accept PayPal on our all our items so you can shop with confidence.
    Simple choose the PayPal option when proceeding through the checkout.
    Additional Information
    No additional information at this time
    Ask seller a question
    You might also like
    1236-17 Thermometer
    1236-70 Espresso Thermometer
    1246-01 Pocket Test Thermometer
    1246-02 Pocket Test Thermometer
    Contact
    To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
    Ask seller a question
    © Tech Instrumentation
    Postage
    Click the Postage tab above the listing description for more info
    Payment
    Accepted Payment Methods
    PayPal
    Returns
    Returns are accepted
    Items must be returned within 30 days of the auction ending
    Buyer will pay for return shipping.