-40%
LogTag TRIL-8 Low Temperature and Dry Ice Temperature Recorder
$ 47.34
- Description
- Size Guide
Description
LogTag TRIL-8 Low Temperature and Dry Ice Temperature RecorderTRIL-8 Records temperature from +40°C to as low as -80°C 'OK' & 'ALERT' Indicator with high and low customizable alarms 8000 reading memory capacity Multi-trip Dry Ice Model Probe-less low Temperature Recorder IMPORTANT: Each location (not each logger) requires a LogTag Cradle in order to program and retrieve data from the logger. The LogTag TRIL-8 dry ice & low temperature sensor operates, measures and stores up to 8000 temperature readings in temperature environments ranging from -80°C to +40°C (-112°F to +104°F). This LogTag recorder is intended for use in transit monitoring of articles stored in packaging incorporating dry ice cooling. Using the LogTag® Interface Cradle and the freely available companion software LogTag® Analyzer, these are easily set-up for recording conditions including delayed start, sampling interval, number of readings, continuous or fixed number of readings and configuration of conditions to activate the 'ALERT' indicator. LogTag® Analyzer also provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as MS Excel once the data has been downloaded. Specifications Model TRIL-8 (Multi-use) Recorder Operating Measurement Range -80°C ~ +40°C (-112°F ~ +104°F) Resolution < than 0.1°C for -80°C ~ +0.0°C < than 0.2°C for -0.0°C ~ +20°C< than 0.5°C for +20°C ~ +40°C (see below) Accuracy Better than ±1°C for -30°C~ +20°CBetter than ±1.2°C for -45°C~ -30°C & +20°C~+40°CBetter than ±1.7°C for -80°C~ -45°C Sensor Reaction Time Typically less than 5 minutes(T90) in moving air (1m/s) Capacity 8000 readings (16K bytes memory) Sampling Frequency Adjustable, 1~60 minutes or 1~18 hours Logging Start Options Push button start or specific date & time. Recording Indication Flashing 'OK' indicator / flashing 'ALERT' indicator. Download Time Typically with full memory (8000 readings) in less than 5 secs depending on computer or readout device used. Environmental IP65 (roughly equivalent to NEMA 4) Power Source 3.6V low temperature chemistry Lithium battery Battery Life Storage life of up to 12 months before ‘start’.Rated for up to 1000 hours of exposure to -80°C. Size 86mm(H)x54.5mm(W)x8.6mm(T) Weight 35g Case Material Polycarbonate Other Features • Logging start by push button or specific date/time start • Optional clearing of alert indication by push button (places inspection make at same time).• Download inspection mark recorded in LogTag memory every time LogTag is downloaded.• 'Prestart' fail-safe logging (records temperature data even if not started)• Low Battery indication in software.• Comprehensive Alert indicator configuration.• Calibration to achieve higher accuracy possible. Compliances EMC Compliance Tested and complies with EC EMC directives (EN 50081-1:1992 & EN 61000-6-1:2001).See LogTag® TRIL-8 & SRIL-8 CE mark EMC declaration of conformance Tested and complies FCC Part 15 Subparts A and B. TRIL-8 & SRIL-8 FCC EMC declaration of conformance FDA CFR21 Part 11 Compliance Designed for FDA CFR21 Part 11 Digital signatures RoHS
LogTag TRIL-8 Low Temperature and Dry Ice Temperature Recorder
TRIL-8
Records temperature from +40°C to as low as -80°C
'OK' & 'ALERT' Indicator with high and low customizable alarms
8000 reading memory capacity
Multi-trip Dry Ice Model
Probe-less low Temperature Recorder
IMPORTANT: Each location (not each logger) requires a LogTag Cradle in order to program and retrieve data from the logger.
The LogTag TRIL-8 dry ice & low temperature sensor operates, measures and stores up to 8000 temperature readings in temperature environments ranging from -80°C to +40°C (-112°F to +104°F). This LogTag recorder is intended for use in transit monitoring of articles stored in packaging incorporating dry ice cooling.
Using the LogTag
®
Interface Cradle and the freely available companion software LogTag
®
Analyzer, these are easily set-up for recording conditions including delayed start, sampling interval, number of readings, continuous or fixed number of readings and configuration of conditions to activate the 'ALERT' indicator.
LogTag® Analyzer also provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as MS Excel once the data has been downloaded.
Specifications
Model
TRIL-8 (Multi-use)
Recorder Operating Measurement Range
-80°C ~ +40°C (-112°F ~ +104°F)
Resolution
< than 0.1°C for -80°C ~ +0.0°C
< than 0.2°C for -0.0°C ~ +20°C
< than 0.5°C for +20°C ~ +40°C (see below)
Accuracy
Better than ±1°C for -30°C~ +20°C
Better than ±1.2°C for -45°C~ -30°C & +20°C~+40°C
Better than ±1.7°C for -80°C~ -45°C
Sensor Reaction Time
Typically less than 5 minutes(
T90
) in moving air (1m/s)
Capacity
8000 readings (16K bytes memory)
Sampling Frequency
Adjustable, 1~60 minutes or 1~18 hours
Logging Start Options
Push button start or specific date & time.
Recording Indication
Flashing 'OK' indicator / flashing 'ALERT' indicator.
Download Time
Typically with full memory (8000 readings) in less than 5 secs depending on computer or readout device uséd.
Environmental
IP65 (roughly equivalent to NEMA 4)
Power Source
3.6V low temperature chemistry Lithium battery
Battery Life
Storage life of up to 12 months before ‘start’.
Rated for up to 1000 hours of exposure to -80°C.
Size
86mm(H)x54.5mm(W)x8.6mm(T)
Weight
35g
Case Material
Polycarbonate
Other Features
• Logging start by push button or specific date/time start
• Optional clearing of alert indication by push button (places inspection make at same time).
• Download inspection mark recorded in LogTag memory every time LogTag is downloaded.
• 'Prestart' fail-safe logging (records temperature data even if not started)
• Low Battery indication in software.
• Comprehensive
Alert
indicator configuration.
• Calibration to achieve higher accuracy possible.
Compliances
EMC Compliance
Tested and complies with EC EMC directives (EN
50081-1:1992
& EN 61000-6-1:2001).
See LogTag
®
TRIL-8 & SRIL-8 CE mark EMC declaration of conformance
Tested and complies FCC Part 15 Subparts A and B.
TRIL-8 & SRIL-8 FCC EMC declaration of conformance
FDA CFR21 Part 11 Compliance
Designed for FDA CFR21 Part 11 Digital signatures
RoHS
×
×
×
Tell a friend
Visit store
Watch now
Postage info
Click the Postage tab above the listing description for more info
Click the Postage tab above the listing description for more info!
Additional delivery notes
PICK UP OPTION
Sorry, our items are NOT available for pick-up.
PAYING VIA PAYPAL
We accept PayPal on our all our items so you can shop with confidence.
Simple choose the PayPal option when proceeding through the checkout.
Additional Information
No additional information at this time
Ask seller a question
You might also like
1236-17 Thermometer
1236-70 Espresso Thermometer
1246-01 Pocket Test Thermometer
1246-02 Pocket Test Thermometer
Contact
To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
Ask seller a question
© Tech Instrumentation
Postage
Click the Postage tab above the listing description for more info
Payment
Accepted Payment Methods
PayPal
Returns
Returns are accepted
Items must be returned within 30 days of the auction ending
Buyer will pay for return shipping.
eBay integration
by